Professional Hand Evaluation Kit
Basic Information
- Brand Name
- Professional Hand Evaluation Kit
- Primary DI
- 00855170007119
- Version / Model
- 5030K1
- Catalog Number
- 5030K1
- Company Name
- LAFAYETTE INSTRUMENT COMPANY, INC.
- Labeler DUNS
- 005080650
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-08-31
- Public Version
- 1
- Public Version Date
- 2021-09-08
- Public Version Status
- New
- Public Device Record Key
- 41facf4b-2b74-4b28-84f4-08b483d3868d
Device Description
The Lafayette Grip or Pinch Dynamometers are hydraulic strength measuring instruments. They are designed for routine assessment of the grip and/or pinch strength of a patient or can also be used in the evaluation of hand trauma or disease. As the patient either grips or pinches the device, a column of hydraulic fluid activates a pressure gauge mounted on the top of the device. The gauge indicates the pinch or grip force in pounds (lbs) or kilogram force (kgf). A peak needle shows the maximum force applied during a single test. The peak needle is manually reset at the end of the test and peak values are recorded manually. The grip dynamometers also feature an adjustable handle that can accommodate five different grip positions. The Stainless Steel Short Finger Goniometer is used for easy range-of-motion measurements of metacarpal, phalangeal, and interphalangeal joints. There are linear inch and centimeter markings on both sides of the protractors, in opposite directions. The protractors measure 0-150° in 5° increments. Stainless steel. Latex free. Clearly marked numbers make measuring easy. Measures 5.75 inches long.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HRW | Dynamometer, Nonpowered | Orthopedic | 888.1250 | 1 |
| KQW | Goniometer, Nonpowered | Orthopedic | 888.1520 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35021 | Hand dynamometer/pinchmeter, mechanical | A non-powered, mechanical instrument designed to assess neuromuscular function by measuring the force or power exerted by the muscles of the hand/forearm to squeeze/pinch an object. It is used to assess a patient's grip and/or pinch strength in clinical or research settings, typically as part of a rehabilitation program for geriatric patients or those who have suffered a stroke. This device is commonly known as a Vigorimeter. It typically consists of various size squeeze bulbs and an analogue manometer to record the exerted effort. The patient will typically be asked to perform the test a few times so that the physician can obtain a mean value. | No | Active |
| 33651 | Manual goniometer | A non-powered, manually-operated measuring device, graduated in degrees (e.g., from 0 to 360 degrees), designed to be used in a clinical setting to measure the range of motion of the limb of a patient by measuring the angle of movement achieved at the joint. It is typically used by rheumatologists, physiotherapists, orthopaedists and general practitioners to evaluate joint movement (e.g., ankle, finger, knee, shoulder or spine) before and after a medical/surgical intervention. It may be made of plastic or stainless steel and is available in various designs (e.g., protractor-like with pivoting arms, dial-like with twin rotating dials). This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00855170007119 | GS1 |
Customer Contacts
- Phone
- 765-423-1505
- [email protected]
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 50 – 95 Degrees Fahrenheit