FDA UDI
In Commercial Distribution
🇺🇸 United States
Cartiva SCI Introducer
DI: 00852897002113
·
Model: INT-10
·
CARTIVA, INC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Cartiva SCI Introducer
- Primary DI
- 00852897002113
- Version / Model
- INT-10
- Catalog Number
- INT-10
- Company Name
- CARTIVA, INC
- Labeler DUNS
- 078582549
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-01-13
- Public Version
- 5
- Public Version Date
- 2023-05-03
- Public Version Status
- Update
- Public Device Record Key
- b2ec97e4-6fe1-4760-8301-3c40faa775ff
Device Description
Surgical Instrument- 10 mm Introducer
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| QBO | Instruments Designed For Press-Fit Osteochondral Implants | Orthopedic | 888.4505 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 13180 | Orthopaedic prosthesis implantation positioning instrument, reusable | A hand-held surgical instrument intended to be used during implantation of an orthopaedic prosthesis, either manually or as a computer-assisted surgery (CAS) device, to aid in the navigation/placement of the prosthesis or other instruments [e.g., drill sleeves and guide wires (Kirschner wires), patella saw guide]. It may be used for the following applications: 1) to hold/align/fix/guide other instruments, prostheses, or prosthesis components; 2) to provide relative position landmarks; 3) to ascertain correct spatial orientation or limb alignment; and/or 4) as an interface (non-adaptive) between prosthesis components. This is a reusable device intended to be sterilized prior to use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00852897002113 | GS1 |
Customer Contacts
- Phone
- 770-754-3800
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| P150017 | 000 |