FDA UDI
In Commercial Distribution
🇺🇸 United States
Insuflow
DI: 00852588007007
·
Model: 6198
·
LEXION MEDICAL, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Insuflow
- Primary DI
- 00852588007007
- Version / Model
- 6198
- Catalog Number
- 6198
- Company Name
- LEXION MEDICAL, LLC
- Labeler DUNS
- 848693730
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-26
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- 4f3a60c6-f3c7-4e2c-8228-c95bfa0e1ad8
Device Description
Laparoscopic gas conditioning device.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Ethylene Oxide
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HIF | Insufflator, Laparoscopic | Obstetrics/Gynecology | 884.1730 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 38559 | Insufflation gas conditioning tubing set | A collection of sterile and non-sterile devices intended to be used with an insufflation gas conditioning system and/or a laparoscopic gas distention system, or other gas source, to condition the insufflation gas stream [typically carbon dioxide (CO2)] by heating and humidifying it before introduction into the peritoneal cavity or a wound during laparoscopic or open surgery. It is available in various configurations but typically includes a connection tube for connection to the gas source, an electrically-heated tube for transport of the conditioned gas to the operative site, a humidification chamber, a gas filter, and connectors. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00852588007007 | GS1 |
Customer Contacts
- Phone
- 6516350000
- [email protected]
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 16 – 27 Degrees Celsius