FDA UDI In Commercial Distribution 🇺🇸 United States

ChestSuite

DI: 00852491008047 · Model: 1.0.0 · Imagen Technologies, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
ChestSuite
Primary DI
00852491008047
Version / Model
1.0.0
Company Name
Imagen Technologies, Inc.
Labeler DUNS
042356781
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2026-04-15
Public Version
1
Public Version Date
2026-04-23
Public Version Status
New
Public Device Record Key
b61b972a-3312-42fb-ba53-171d1d9b228d

Device Description

ChestSuite is a software bundle that aggregates the functionalities and outputs of three FDA clearances: Aorta-CAD (AC) and Lung-CAD (LC), and Lung-CAD (LC). The indications for use are as follows: AC is a computer-assisted detection (CADe) software device that analyzes chest radiograph studies for suspicious regions of interest (ROIs). The device uses a deep learning algorithm to identify ROIs and produces boxes around the ROIs. The boxes are labeled with one of the following radiographic findings: Aortic calcification or Dilated aorta. AC is intended for use as a concurrent reading aid for physicians looking for ROIs with radiographic findings suggestive of Aortic Atherosclerosis or Aortic Ectasia. It does not replace the role of the physician or of other diagnostic testing in the standard of care. AC is indicated for adults only. LC is a computer-assisted detection (CADe) software device that analyzes chest radiograph studies for lung hyperinflation. The device uses a deep learning algorithm to identify ROIs with lung hyperinflation and produces boxes around the ROIs. LC is intended for use as a concurrent reading aid for physicians interpreting chest X-rays. The device is not intended for clinical diagnosis of any disease. It does not replace the role of the physician or of other diagnostic testing in the standard of care for lung parenchymal findings. LC is indicated for adults only. LC is a computer-assisted detection (CADe) software device that analyzes chest radiograph studies for interstitial thickening. The device uses a deep learning algorithm to identify ROIs with interstitial thickening and produces boxes around the ROIs. LC is intended for use as a concurrent reading aid for physicians interpreting chest X-rays. The device is not intended for clinical diagnosis of any disease. It does not replace the role of the physician or of other diagnostic testing in the standard of care for lung parenchymal findings. Lung-CAD is indicated for adults only.

Device Characteristics

Single Use
No
Prescription Use (Rx)
No
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
No
Has Manufacturing Date
No
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
MYN Analyzer, Medical Image

GMDN Terms

Code Name
63386 X-ray image interpretive software

Identifiers

Type ID
Primary 00852491008047

Premarket Submissions

Submission Number Supplement Number
K213353 000
K223811 000
K230085 000