FDA UDI In Commercial Distribution 🇺🇸 United States

Wildcat

DI: 00851354004028 · Model: E400 · AVINGER, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
Wildcat
Primary DI
00851354004028
Version / Model
E400
Catalog Number
E400
Company Name
AVINGER, INC.
Labeler DUNS
003152968
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2019-03-21
Public Version
1
Public Version Date
2019-03-29
Public Version Status
New
Public Device Record Key
1c509c09-1f04-489d-907f-f0989764bbf4

Device Description

"The Wildcat CTO Catheter is intended to create a channel in totally occluded peripheral vessels. The device may also be used to faciliate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Wildcat CTO Catheter is a 6F sheath and 0.035"" guidewire compatible over-the-wire device. It consists of a catheter shaft with a handle assembly at the porximal end and an atraumatic Distal Tip. A locking Luer connector at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only. At the Slider’s most proximal location, the Wedges are in the retracted position. At the mid-point location, the Wedges are deployed. Moving the slider distal from this point initiates deflection of the Distal Tip. The amount of tip deflection increases with distal movement of the slider. At the most distal location, the Wedges remain fully deployed and the Distal Tip is at maximum deflection. The deployment and retraction of the Wedges as well as the deflection of the Distal Tip is visible under fluoroscopic guidance. The handle assembly consists of a Handle Body, Rotator, Tip Indicator, Slider, and Luer. The Handle Body controls rotational orientation of the catheter, including the flexible Distal Tip. The Rotator controls the rotational movement of the Distal Tip, independent of the catheter orientation. Rotational movement of the Distal Tip can be achieved either with Wedges deployed or retracted. Luer is provided to facilitate fluid flush and the entry/exit of the guidewire. "

Device Characteristics

Single Use
Yes
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
Yes
Has Lot/Batch Number
Yes
Has Manufacturing Date
Yes
Has Expiration Date
Yes
Has Donation ID
No

Sterilization

Is Sterile
Yes
Sterilization Prior Use
Yes
Sterilization Methods
Radiation Sterilization

Product Codes

Code Name
DQY Catheter, Percutaneous

GMDN Terms

Code Name
44307 Mechanical atherectomy system catheter, peripheral

Identifiers

Type ID
Primary 00851354004028

Customer Contacts

Phone
650-241-7030