FDA UDI In Commercial Distribution 🇺🇸 United States

NeVasc .070 Aspiration Catheter, 132 cm

DI: 00851279008989 · Model: VC-070-132 · Vesalio
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
NeVasc .070 Aspiration Catheter, 132 cm
Primary DI
00851279008989
Version / Model
VC-070-132
Catalog Number
VC-070-132
Company Name
Vesalio
Labeler DUNS
080986009
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2026-03-26
Public Version
1
Public Version Date
2026-04-03
Public Version Status
New
Public Device Record Key
81472fb2-4819-4ae0-8f84-77ef85d0a291

Device Description

The NeVasc Aspiration System consists of 1) NeVasc Aspiration Catheter, 2) Peel away Introducer Sheath and 3) an Aspiration Tubing Set NeVasc Aspiration Catheter: The NeVasc Aspiration Catheter (also referred to as NeVasc Catheter) is a single lumen, reinforced, flexible, variable stiffness composite catheter. The catheter distal shaft has an external hydrophilic coating aimed to reduce friction during use. The distal end of the catheter shaft is radiopaque for angiographic visualization, and the proximal end contains a luer hub that allows attachment of accessories for flushing and aspiration. Complete dimensions of the catheter are included on the device label. The Peel-Away Introducer is an accessory provided with the catheter to aid in the delivery of the catheter. The NeVasc Catheter and a Peel-Away Introducer are packaged together, they are provided sterile, non-pyrogenic, and are intended for single use only. Aspiration Tubing Set: As part of the NeVasc Aspiration System, the Vesalio Aspiration Tubing Set is provided with a flow switch and is intended to connect the NeVasc Catheter to a compatible aspiration pump. The Aspiration Tubing Set is intended for single use and is provided in a separate package.

Device Characteristics

Single Use
Yes
Prescription Use (Rx)
No
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
Yes
Has Manufacturing Date
No
Has Expiration Date
Yes
Has Donation ID
No

Sterilization

Is Sterile
Yes
Sterilization Prior Use
No

Product Codes

Code Name
NRY Catheter, Thrombus Retriever

GMDN Terms

Code Name
58173 Thrombectomy suction catheter

Identifiers

Type ID
Primary 00851279008989

Premarket Submissions

Submission Number Supplement Number
K251006 000