FDA UDI
In Commercial Distribution
🇺🇸 United States
SWICKER
DI: 00850049993609
·
Model: 4008-203
·
Syntervention, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
2
Basic Information
- Brand Name
- SWICKER
- Primary DI
- 00850049993609
- Version / Model
- 4008-203
- Catalog Number
- 4008-203
- Company Name
- Syntervention, Inc.
- Labeler DUNS
- 025315999
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 2
- Record Status
- Published
- Publish Date
- 2023-11-09
- Public Version
- 1
- Public Version Date
- 2023-11-17
- Public Version Status
- New
- Public Device Record Key
- 5a3b59f1-7d56-4576-bc86-51c310b28193
Device Description
The SWICKER is a sterile, highly absorbent medical accessory product intended for use in variety of surgical or medical procedures. Comprised primarily of a form of polyurethane, it has many uses including in areas such as open surgery, laparoscopic surgery, and wound care.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GDY | Gauze/Sponge, Internal, X-Ray Detectable | General, Plastic Surgery | 878.4450 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 39404 | Radiopaque non-woven surgical sponge | A non-medicated device made from a non-woven absorbent material (e.g., rayon/polyester) primarily intended to be used inside the body, on a surgical incision or applied to internal organs or structures to control bleeding, absorb fluid, or protect organs or structures from abrasion, drying, or contamination during a procedure; also referred to as a laparotomy sponge, it may also be used for prepping the patient. It is intended to produce less lint than woven gauze and contains an x-ray detectable marker [e.g., a thread or strand(s)] to help detect gossypiboma (sponge left inside patient). This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Unit of Use | 00850049993029 | GS1 | ||||
| Primary | 00850049993609 | GS1 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 1.5 | Inch | |
| Width | 3 | Inch | |
| Height | 0.125 | Inch |