FDA UDI In Commercial Distribution 🇺🇸 United States

circul pro, small

DI: 00850033422061 · Model: O2-77-MS · BodiMetrics, LLC
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1

Let the assistant research this device

The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.

Free to try · every answer cites its records

Basic Information

Brand Name
circul pro, small
Primary DI
00850033422061
Version / Model
O2-77-MS
Company Name
BodiMetrics, LLC
Labeler DUNS
079854070
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2025-02-21
Public Version
1
Public Version Date
2025-03-03
Public Version Status
New
Public Device Record Key
31023aab-b351-4b1a-8edb-b9772188fd90

Device Description

The circul pro Ring is a small, wearable, non-invasive device to be worn on one finger which features an adjustable fit for comfort. It can be worn on either hand. The ring has a retractable spring design, which automatically adjusts the tightness of the ring and fixates the sensor array to the wearer’s finger. The ring has advanced photoelectric signal detection and processing methods which detect and analyze blood oxygen saturation and pulse rate. The circul™ pro Ring is a wireless, non-invasive, and stand-alone pulse oximeter intended to be used for spot-check and/or continuous data collection of oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) through the index finger in adult patients. It can be used in hospitals and home environments for up to twelve hours in non-motion and well perfused conditions.

Device Characteristics

Single Use
No
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
Yes
PM Exempt
No
Has Serial Number
Yes
Has Lot/Batch Number
Yes
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
DQA Oximeter

GMDN Terms

Code Name
12391 Wearable multiple physiological parameter recorder, reusable

Identifiers

Type ID
Primary 00850033422061
Package 30850033422086

Customer Contacts

Phone
8447448800

Premarket Submissions

Submission Number Supplement Number
K221361 000

Device Sizes

Type Value Unit Text
Lumen/Inner Diameter 18 Millimeter

Storage Conditions

Type
Storage Environment Temperature
Temperature Range
-10 – 50 Degrees Celsius
Type
Storage Environment Humidity
Temperature Range
15 – 95 Percent (%) Relative Humidity
Type
Storage Environment Atmospheric Pressure
Temperature Range
50 – 107.4 KiloPascal