FDA UDI
In Commercial Distribution
🇺🇸 United States
Bertec Head Mounted Display System (HMD)
DI: 00850017250116
·
Model: 97P-0109
·
BERTEC CORPORATION
Product Codes
2
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Bertec Head Mounted Display System (HMD)
- Primary DI
- 00850017250116
- Version / Model
- 97P-0109
- Company Name
- BERTEC CORPORATION
- Labeler DUNS
- 619142540
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-02-08
- Public Version
- 2
- Public Version Date
- 2024-02-05
- Public Version Status
- Update
- Public Device Record Key
- 1b7ac179-54db-4232-8f8e-dae08e522026
Device Description
Bertec Balance Advantage Head Mounted Display (HMD) system is a clinical balance assessment device that collects and analyzes force and movement data from a static balance plate with Head Mounted Display (HMD) to enhance clinical balance assessment and training.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| ISD | Exerciser, Measuring | Physical Medicine | 890.5360 | 2 |
| KHX | Platform, Force-Measuring | Physical Medicine | 890.1575 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47518 | Biomechanical function analysis/rehabilitation software | A software package intended to be used by patients and clinicians to receive and display a patient’s physical exercise/movement/action data [e.g., kinesiology/gait data (walking speed or distance)] to facilitate analysis as part of physical assessment/rehabilitation. It is intended to be used while using an interactive rehabilitation system, biomechanical function analysis system and/or kinesiology recorder (ambulatory or implantable). It might be intended to function in conjunction with a motion-sensing system/device or limb-support robotic system, and may be capable of storing and/or enable viewing of patient performance data. | No | Active |
| 17242 | Posturography system | An assembly of devices designed to test a patient's sensory, voluntary, and/or reflexive motor control of balance and mobility providing biofeedback for rehabilitation of balance problems. The patient is placed on a dedicated platform equipped with built-in sensors, transducer and/or force plates that register movement when he/she adjusts his/her centre of gravity (COG) alignment according to the doctor's instructions, or, the platform provokes destabilizing perturbations and the output is recorded to a computer where they are graphically reproduced. This device is used, e.g., for motor control test (MCT), posture studies, balance, mobility training, and/or sense of equilibrium studies. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00850017250116 | GS1 |
Customer Contacts
- Phone
- 1-614-543-8099
- [email protected]