FDA UDI
In Commercial Distribution
🇺🇸 United States
myCordella Handheld Patient Reader Alloy
DI: 00850008997143
·
Model: 100102-02
·
Endotronix, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- myCordella Handheld Patient Reader Alloy
- Primary DI
- 00850008997143
- Version / Model
- 100102-02
- Company Name
- Endotronix, Inc.
- Labeler DUNS
- 806850835
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-10-13
- Public Version
- 1
- Public Version Date
- 2025-10-21
- Public Version Status
- New
- Public Device Record Key
- 0e265f0f-4e43-43d9-929e-239c7f98fe24
Device Description
The Cordella Pulmonary Artery Sensor System is designed for on-demand measurement of pulmonary artery pressure from the patient’s home. myCordella Handheld Patient Reader is a component of the Cordella Pulmonary Artery Sensor System. The myCordella Handheld Patient Reader (Reader) is a handheld device that is provided to the patient for at-home use to measure PA pressure on demand. The Reader wirelessly transmits the raw data obtained from the Cordella Sensor to the myCordella Tablet. The raw data is converted into readable data and sent to the myCordella Patient Management Portal for the clinician to review.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MOM | System, Hemodynamic, Implantable | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61178 | Implantable pulmonary artery pressure monitoring system | An assembly of devices intended for regular (e.g., daily) measurement and recording of pulmonary artery pressures, to assist monitoring and treatment of a heart disease patient at high-risk of heart failure. It includes a sensor intended to be implanted in the pulmonary artery, an external monitoring system(s), information software, and typically devices associated with implantation. The monitoring system(s) are intended to wirelessly power and interrogate the implanted sensor via an antenna, and display/record/communicate arterial blood pressure information (e.g., systolic, diastolic and mean pressures, heart rate). It is intended for monitoring in both the home and healthcare facility. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00850008997143 | GS1 |
Customer Contacts
- Phone
- +1 888 512 5595
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| P230040 | 012 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- -10 – 55 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 6 – 93 Percent (%) Relative Humidity