FDA UDI
Not in Commercial Distribution
🇺🇸 United States
GIBI HD
DI: 00850007764210
·
Model: B-2032
·
Reshape Lifesciences Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- GIBI HD
- Primary DI
- 00850007764210
- Version / Model
- B-2032
- Catalog Number
- B-2032
- Company Name
- Reshape Lifesciences Inc.
- Labeler DUNS
- 144998551
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-08-07
- Public Version
- 6
- Public Version Date
- 2023-07-28
- Public Version Status
- Update
- Public Device Record Key
- 7f2776a2-f6a1-4e78-8101-4e96ca3cb37c
- Distribution End Date
- 2023-03-16
Device Description
Gastrointestinal Boundary Identification and Sizing Tube 32 French
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KNT | Tubes, Gastrointestinal (And Accessories) | Gastroenterology, Urology | 876.5980 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44686 | Gastric calibration tube | A thin, flexible, hollow cylinder with an inflatable balloon at the distal end designed to be inserted into a patient's stomach through the mouth and oesophagus to create and size a gastric pouch typically for a bariatric gastric surgical procedure (e.g., sleeve gastrectomy, gastric banding). The proximal end may include a check valve and connects to a syringe, typically included, intended to inflate the balloon to a predetermined volume; fluid suction/irrigation ports are provided at the distal end. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00850007764210 | GS1 |
Customer Contacts
- Phone
- 844-937-7374
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K221898 | 000 |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Do Not Use if Package is Damaged