FDA UDI
In Commercial Distribution
🇺🇸 United States
RetroFix
DI: 00850005757337
·
Model: 90L:PROX5.5-25L:DIST4 TI
·
RETROFIX SCREWS, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- RetroFix
- Primary DI
- 00850005757337
- Version / Model
- 90L:PROX5.5-25L:DIST4 TI
- Catalog Number
- CTM000758-033 TI
- Company Name
- RETROFIX SCREWS, LLC
- Labeler DUNS
- 069485021
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-12-23
- Public Version
- 2
- Public Version Date
- 2024-02-19
- Public Version Status
- Update
- Public Device Record Key
- 0802684d-7338-437e-ba3d-1a3577ecf303
Device Description
CANNULATED TAPERED SCREW OVERALL LENGTH 90MM PROXIMAL DIAMETER 5.5MM PROXIMAL LENGHT 25MM DISTAL DIAMETER 4MM MATERIAL: TI
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HWC | Screw, Fixation, Bone | Orthopedic | 888.3040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 56642 | Orthopaedic bone screw, non-bioabsorbable, non-sterile | A small, non-sterile, threaded rod with a slotted head typically used for internal orthopaedic fracture fixation by being screwed into bone to hold plates or nails to bone or to provide direct interfragmentary stabilization of bone, or it may fasten soft tissue to bone; it is made of a material that cannot be chemically degraded or absorbed via natural body processes (includes implant grade metal such as surgical steel, titanium alloy, or carbon fibre). Screws available are: cortical, cancellous, malleolar, scaphoid, partially-threaded and fully-threaded, self-tapping, and cannulated. A "lag screw" can be any of these used to obtain compression. This device must be sterilized prior to use. | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00850005757337 | GS1 |
Customer Contacts
- Phone
- 19804328412
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K200226 | 000 |