FDA UDI
In Commercial Distribution
🇺🇸 United States
Element System with IBT Electrodes
DI: 00850004850008
·
Model: 80101-1
·
INFINITE BIOMEDICAL TECHNOLOGIES, LLC
Product Codes
2
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Element System with IBT Electrodes
- Primary DI
- 00850004850008
- Version / Model
- 80101-1
- Company Name
- INFINITE BIOMEDICAL TECHNOLOGIES, LLC
- Labeler DUNS
- 037376022
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-02-23
- Public Version
- 2
- Public Version Date
- 2023-12-18
- Public Version Status
- Update
- Public Device Record Key
- 979c5d2a-0f4e-415c-bbbf-0ff079cebe37
Device Description
Surface electrodes for Electromyography with controller - Coaxial Plug or Ottobock Wrist
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GXY | Electrode, Cutaneous | Neurology | 882.1320 | 2 |
| IQZ | Hand, External Limb Component, Powered | Physical Medicine | 890.3420 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 41497 | Myoelectric hand prosthesis | A powered artificial substitute for a missing hand that may be attached to a natural arm or used as part of an upper-limb external prosthetic system, and is designed to replace the appearance and some of the function of the hand. The device moves as the result of a motor(s) that may be integral or proximally mounted with a mechanical link. The control of movement is achieved through amplified muscle action potentials from voluntary contracting muscle in the residual limb/trunk, transmitted via surface electrodes in the device that make contact with the skin, which turn on the motor to provide a function. | No | Active |
| 61020 | Analytical non-scalp cutaneous electrode | An electrical conductor designed to be attached to the skin surface of a patient outside of the hair line (i.e., non-scalp) to conduct electrical signals to/from a parent device for electrophysiological recording/monitoring [e.g., electromyography (EMG), evoked potentials (EP), nerve conduction study (NCS), bioelectrical impedance]; it is not primarily intended for diagnostic electrocardiography (ECG) or electroencephalography (EEG). It typically consists of a small rectangular tab or cup/disk with a conductive surface, which may include a lead wire. This is a single-patient device that may be reapplied to the patient over a short term (single-use) before being discarded. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00850004850008 | GS1 |
Customer Contacts
- Phone
- 4434517175
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K173571 | 000 |