FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Key Surgical K-Wires and Steinmann Pins
DI: 00849771012153
·
Model: KI-71-032
·
KEY SURGICAL, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
6
Basic Information
- Brand Name
- Key Surgical K-Wires and Steinmann Pins
- Primary DI
- 00849771012153
- Version / Model
- KI-71-032
- Company Name
- KEY SURGICAL, INC.
- Labeler DUNS
- 604056226
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 6
- Record Status
- Published
- Publish Date
- 2020-12-21
- Public Version
- 5
- Public Version Date
- 2023-09-18
- Public Version Status
- Update
- Public Device Record Key
- ed5517e3-d895-4d53-9ff8-5c3e5bb18cbd
- Distribution End Date
- 2023-01-18
Device Description
K-Wires, Double diamond, .045-inch (1.1mm) diameter, 6-inch long
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HTY | Pin, Fixation, Smooth | Orthopedic | 888.3040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 32854 | Orthopaedic bone pin, non-bioabsorbable | A thin, implantable rod intended to be used for the stabilization of a bone fracture or bone grafts, or for an osteotomy or arthrodesis. It is typically drilled into bone and may be smooth or threaded, solid or cannulated, and/or semi-flexible. Also known as a K-Wire, it may in addition be intended to assist with the introduction of a surgical instrument and/or implant; it is not intended for implantation into the intramedullary canal (i.e., not a nail). It is made of a material that is not chemically degraded or absorbed by natural body processes (e.g., stainless steel). Some designs may have a break-off shank and/or be coated to improve long-term fixation. This is a single-use device. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Unit of Use | 00849771044314 | GS1 | ||||
| Primary | 00849771012153 | GS1 |
Customer Contacts
- Phone
- +1(800)541-7995
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K102845 | 000 |