FDA UDI
In Commercial Distribution
🇺🇸 United States
Thermogard HQTM Start-Up Kit
DI: 00849111075862
·
Model: TG2-500D
·
Zoll Circulation, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Thermogard HQTM Start-Up Kit
- Primary DI
- 00849111075862
- Version / Model
- TG2-500D
- Catalog Number
- 8700-001027-01
- Company Name
- Zoll Circulation, Inc.
- Labeler DUNS
- 799455241
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-06-27
- Public Version
- 2
- Public Version Date
- 2023-12-18
- Public Version Status
- Update
- Public Device Record Key
- a8aa4db3-f87c-4967-94f5-5946e5bb59ef
Device Description
The ZOLL® Intravascular Temperature Management (IVTM™) System is comprised of an external heat exchange console (Thermogard HQ™ console) and intravascular heat exchange catheter connected via a sterile heat exchanger and tubing circuit (Thermogard HQTM Start-Up Kit or Thermogard HQTM Start-Up Kit EX). These components together comprise a patient temperature regulation apparatus employing feedback control. The subject devices of this submission are the proposed Thermogard HQTM Console, Thermogard HQTM Start-Up Kit and Thermogard HQTM Start-Up Kit EX.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Safe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- Yes
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NCX | System, Hypothermia, Intravenous, Cooling | Cardiovascular | 870.5900 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46315 | Intravascular core temperature regulation system start kit | A collection of devices intended to be used to facilitate the function of intravascular core temperature regulation system. It typically includes tubing to connect the pump mechanism of the control unit, a heat exchange coil, a spike for insertion into the bag of fluid used in the system (e.g., normal saline), an air trap, a flow indicator, and a Luer-lock connection for the intravascular catheter. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00849111075862 | GS1 |
Customer Contacts
- Phone
- 4085412140
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 6 | Feet |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 15 – 40 Degrees Celsius