FDA UDI
In Commercial Distribution
🇺🇸 United States
RESTORIS PST
DI: 00848486016210
·
Model: 188613
·
MAKO SURGICAL CORP.
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- RESTORIS PST
- Primary DI
- 00848486016210
- Version / Model
- 188613
- Catalog Number
- 188613
- Company Name
- MAKO SURGICAL CORP.
- Labeler DUNS
- 175239677
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-12-11
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- c5b0faa9-dfd1-4323-8113-187a94d6e79f
Device Description
Porous Tibial Baseplate
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HRY | PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER | Orthopedic | 888.3530 | 2 |
| NJD | PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, UNICOMPARTMENTAL/UNICONDYLAR, UNCEMENTED, POROUS-COATED, METAL/POLYMER | Orthopedic | 888.3535 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 48065 | Coated unicondylar knee tibia prosthesis | A sterile implantable device designed to replace the bearing surface of one tibial condyle (tibial component) during primary or revision unicompartmental replacement of the knee joint. It is made of metal [e.g., cobalt-chrome (Co-Cr)] and is coated with a material (e.g., beads, hydroxyapatite, mesh) intended to improve fixation and stability by promoting bone ingrowth. The device articulates with a femoral component and an insert, and its implantation may be performed with or without bone cement. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00848486016210 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K133811 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Size: 3 | ||
| Device Size Text, specify | Side: Right Medial/Left Lateral |