FDA UDI
In Commercial Distribution
🇺🇸 United States
InHealth Technologies
DI: 00848253003665
·
Model: VP 2206-LEF
·
Freudenberg Medical, LLC
Product Codes
1
GMDN Terms
3
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- InHealth Technologies
- Primary DI
- 00848253003665
- Version / Model
- VP 2206-LEF
- Company Name
- Freudenberg Medical, LLC
- Labeler DUNS
- 120981337
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-02-03
- Public Version
- 1
- Public Version Date
- 2021-02-11
- Public Version Status
- New
- Public Device Record Key
- daec0422-4547-409d-9e7e-ef1476dfd8ee
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| EWL | Prosthesis, Laryngeal (Taub) | Ear, Nose, Throat | 874.3730 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 42533 | Tracheoesophageal speech valve, indwelling | A device designed to be inserted into a surgically-created tracheo-oesophageal fistula after total laryngectomy to provide the patient with voice restoration. It is inserted and replaced on an as needed basis by a speech pathologist or clinician. It has a double flange (one on the outside of the throat and one on the inside) to hold it in place and includes a one-way valve that protects the airway during swallowing and opens under positive pressure so that air crosses into the oesophagus to produce voice (speech rehabilitation). The patient periodically cleans the device in situ. Disposable devices associated with implantation/insertion may be included. This is a single-use device. | Yes | Active |
| 62134 | Tracheoesophageal device insertion capsule | A non-sterile, smooth, capsule-like device intended to house/cover a tracheoesophageal device (e.g., speech valve, fistula gauge) at the distal end of the introduction assembly, to enable atraumatic insertion of the device into the tracheoesophageal fistula (puncture). It is a synthetic polymer gelatinous casing intended to dissolve in situ for subsequent digestion; disposable devices intended to assist mounting may be included. It is intended to be used in the home and healthcare facility, and may be used in conjunction with a lubricant. This is a single-use device. | No | Active |
| 62127 | Tracheoesophageal device introducer | A hand-held manual instrument designed to assist in the non-surgical placement of a tracheoesophageal device (e.g., speech valve, speech valve occluder, fistula gauge/dilator). It is a synthetic polymer holder onto which the tracheoesophageal device is distally mounted and directed to the target site through the tracheostoma. It is intended to be used by the patient at home (for non-indwelling devices) and clinician in the healthcare facility (for indwelling devices). This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00848253003665 | GS1 |
Customer Contacts
- Phone
- 800-477-5969
- [email protected]
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep away from sunlight; Keep dry