FDA UDI
In Commercial Distribution
🇺🇸 United States
InHealth Technologies; Blom-Singer
DI: 00848253003399
·
Model: PK 2100
·
Freudenberg Medical, LLC
Product Codes
5
GMDN Terms
6
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- InHealth Technologies; Blom-Singer
- Primary DI
- 00848253003399
- Version / Model
- PK 2100
- Company Name
- Freudenberg Medical, LLC
- Labeler DUNS
- 120981337
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-06-07
- Public Version
- 4
- Public Version Date
- 2023-11-03
- Public Version Status
- Update
- Public Device Record Key
- 63dd46a4-999f-426b-98eb-9140b3bff105
Device Description
Post-Operative Care Kit with 9/55 Tube & ClassicFlow HME
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KGX | Tape And Bandage, Adhesive | General Hospital | 880.5240 | 1 |
| CBH | Device, Fixation, Tracheal Tube | Anesthesiology | 868.5770 | 1 |
| BYD | Condenser, Heat And Moisture (Artificial Nose) | Anesthesiology | 868.5375 | 1 |
| KAC | Tube, Laryngectomy | Ear, Nose, Throat | 874.4420 | 1 |
| EWL | Prosthesis, Laryngeal (Taub) | Ear, Nose, Throat | 874.3730 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62047 | Tracheostoma shower shield | A non-sterile, waterproof, patient-worn device intended to cover a tracheal stoma or tracheostomy tube to prevent inhalation of water during showering. It is typically in the form of a waterproof bib worn around the patient’s neck. This is a reusable device intended for single-patient use. | No | Active |
| 62155 | Tracheostomy base plate, reusable | A non-sterile flexible device designed to adhere to the skin around a tracheostoma to function as an anchor for a tracheostomal device (e.g., shower shield, hands-free speech valve). It is made of synthetic polymer and/or metal materials and is available in various forms (e.g., an annular disc with a slightly protruding hollow centre designed to accept the intended device, or a ring on a vertical support); it may include an adhesive backing or be intended to adhere with a separate medical adhesive or tape. This is a reusable device. | No | Active |
| 62175 | Removable ambulatory appliance skin-adherent patch | A patch with a pressure-sensitive adhesive coating designed to be adhered to the skin to temporarily secure/affix a removable patient-worn ambulatory appliance (e.g., tracheostomy base plate, insulin infusion pump) to the body. It is made of synthetic polymer materials [e.g., polyurethane] and is available in various designs (e.g., round, slot, spiral, with a central opening to fit the wearable appliance). It is not intended to adhere an external aesthetic restoration prosthesis (e.g., artificial nose, breast prosthesis) to the skin surface. This is a single-use device. | No | Active |
| 35530 | Heat/moisture exchanger, single-use | A one-piece, canister-like device that connects in-line with a patient's artificial airway [e.g., an endotracheal (ET) tube], to capture the patient's exhaled heat and moisture so that they can be used to heat and humidify therapeutic gases inspired by the patient; it does not include a microbial filter. Commonly known as a heat & moisture exchanger (HME) or an "artificial nose", it is used when the patient is subjected to extended periods of breathing dry gases such as during anaesthesia or intensive care ventilation. This is a single-use device. | No | Active |
| 62136 | Laryngectomy tube, non-sterile | A non-sterile hollow device intended to maintain tracheostoma patency after laryngectomy to provide an airway for the patient and to prevent tracheostomal stenosis in the months following the procedure. It is a soft plastic or silicone curved tube, similar to a tracheostomy tube, contoured to fit the postoperative tracheal anatomy, and may have an inner cannula and be fenestrated to allow simultaneous use with a tracheoesophageal speech valve. It is held in place with a strap or band around the neck and is typically regularly removed and reinserted by the patient. This is a reusable device. | No | Obsolete |
| 35752 | Tracheostomy tube neck holder, reusable | A noninvasive device designed to be fastened around the neck of a patient to secure a tracheostomy device (tube, button) in situ. It is typically in the form of a dedicated strap/collar intended to connect to the tracheostomy device, which is not included. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00848253003399 | GS1 |
Customer Contacts
- Phone
- 800-477-5969
- [email protected]