FDA UDI
Not in Commercial Distribution
🇺🇸 United States
DRLock™
DI: 00846832032389
·
Model: DRV-121-20-20
·
TORNIER, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- DRLock™
- Primary DI
- 00846832032389
- Version / Model
- DRV-121-20-20
- Catalog Number
- DRV-121-20-20
- Company Name
- TORNIER, INC.
- Labeler DUNS
- 968990812
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-16
- Public Version
- 7
- Public Version Date
- 2025-02-06
- Public Version Status
- Update
- Public Device Record Key
- c6f63184-8f94-452d-a032-e13716d63a24
- Distribution End Date
- 2019-12-20
Device Description
Distal Locking Peg
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HRS | PLATE, FIXATION, BONE | Orthopedic | 888.3030 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 66947 | Orthopaedic bone screw (non-sliding) | A small, threaded, non-bioabsorbable, implantable rod intended for internal orthopaedic fixation by being screwed into a limb bone, rib, the sternum and/or pelvis to hold a plate, nail, rod or prosthesis to the bone, or to provide direct interfragmentary stabilization of a fractured bone; it is not intended to be introduced through the sleeve of a femoral neck fixation plate/sleeve, not used in dentistry/orthodontics, craniofacial or spinal bones, and not dedicated to intramedullary fixation/arthrodesis. It is typically of cortical or cancellous design and has a drive (e.g., slot, cross, star, polygonal) at its proximal end for introduction with a screwdriver. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00846832032389 | GS1 |
Customer Contacts
- Phone
- +1(888)494-7950
- [email protected]