FDA UDI
In Commercial Distribution
🇺🇸 United States
SCANLAN® Minimally-Invasive Instrumentation
DI: 00846159025484
·
Model: 9009-528
·
SCANLAN INTERNATIONAL INC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- SCANLAN® Minimally-Invasive Instrumentation
- Primary DI
- 00846159025484
- Version / Model
- 9009-528
- Catalog Number
- 9009-528
- Company Name
- SCANLAN INTERNATIONAL INC
- Labeler DUNS
- 023055619
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-11-22
- Public Version
- 1
- Public Version Date
- 2019-12-02
- Public Version Status
- New
- Public Device Record Key
- 4d96f60d-31a5-4d4e-ac93-c7aedf8a2dec
Device Description
Thoracoscopic Chitwood DeBakey Forcep,5mm,round axial handle,8mm knurl, 2.5 mm straight Debakey jaws without ratchet
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GCJ | Laparoscope, General & Plastic Surgery | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62466 | Surgical soft-tissue manipulation forceps, tweezers-like, reusable | A hand-held, manual, open-surgery instrument designed to facilitate grasping and manipulation of soft-tissues. It has a tweezers-like design (may be a micro/fine instrument) with variously designed tips at the working end, whereby the blades are designed to be opened/closed by squeezing between the fingers (i.e., without ring handles). It is made of high-grade stainless steel, available in various sizes, and may have carbide inserts at the working end. It is not an electrosurgical device and not dedicated to ophthalmic surgery. This is a reusable device intended to be sterilized prior to use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00846159025484 | GS1 |
Customer Contacts
- Phone
- 651-298-0997
- [email protected]