FDA UDI
In Commercial Distribution
🇺🇸 United States
LTV
DI: 00845873004195
·
Model: 18888-009
·
Carefusion Corporation
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- LTV
- Primary DI
- 00845873004195
- Version / Model
- 18888-009
- Company Name
- Carefusion Corporation
- Labeler DUNS
- 830432451
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-09-29
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- aa618a4b-b7b6-4687-aad6-d32c31e853f4
Device Description
ASSY, LTV1200, W/ ACCESS, CHINESE
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CBK | Ventilator, Continuous, Facility Use | Anesthesiology | 868.5895 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36289 | Transport electric ventilator | An electrically-powered device designed to provide automated, alveolar ventilatory support for patients during interhospital or intrahospital transport, and in emergency situations. It is typically a compact, lightweight, rugged device with internal batteries to power it during patient transport. It typically provides mandatory breaths at pre-set intervals (control mode), not allowing the patient to breathe spontaneously; operation in assist/control and/or synchronized intermittent mandatory ventilation (SIMV) modes is available in some types. It usually includes an airway pressure monitor and low and high pressure alarms; it may be used in ambulances, and in field hospitals. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00845873004195 | GS1 |