FDA UDI
In Commercial Distribution
🇺🇸 United States
BV Medical
DI: 00845821025838
·
Model: 20-182-190-L
·
BV Medical
Product Codes
6
GMDN Terms
6
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- BV Medical
- Primary DI
- 00845821025838
- Version / Model
- 20-182-190-L
- Company Name
- BV Medical
- Labeler DUNS
- 105932508
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-09-24
- Public Version
- 8
- Public Version Date
- 2024-11-25
- Public Version Status
- Update
- Public Device Record Key
- 421354de-a941-42fa-a644-5f02afaf4138
Device Description
EMT 5, Infant, Child, Adult, Large Adult, Thigh, Nylon Cuff, Orange, Latex Free, Includes: Palm Gauge, Utility Scissors, Tourniquets, Taylor Hammer, Dual Head Orange Stethoscope
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GWZ | Percussor | Neurology | 882.1700 | 1 |
| KYT | Light, Examination, Medical, Battery Powered | General Hospital | 880.6350 | 1 |
| LRW | Scissors, General, Surgical | General, Plastic Surgery | 878.4800 | 1 |
| GAX | Tourniquet, Nonpneumatic | General, Plastic Surgery | 878.5900 | 1 |
| LDE | Stethoscope, Manual | Cardiovascular | 870.1875 | 1 |
| DXQ | Blood Pressure Cuff | Cardiovascular | 870.1120 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 11950 | Percussion hammer, manual, reusable | A hand-held manual instrument designed to be used by an examining physician to gently tap near a patient's joints to test reflexes (e.g., patellar, ankle reflexes). It consists of a handle and shaft typically made of stainless steel, and has a head that may be ring, wedge, or dome shaped and is made of a soft material (e.g., rubber or plastic). Some devices may be fitted with a spike, brush, or other detachable component at the proximal end that can be used for neurological examinations. This is a reusable device. | No | Active |
| 13755 | Mechanical external stethoscope | A non-powered, external listening device designed to be placed on the patient’s skin to listen sounds from the arms, heart, lungs, and/or gastrointestinal tract. It typically comprises a membrane at the listening head connected by a split "Y" tube to the headgear with ear olives that are placed into the user’s ears. This is a reusable device. | No | Active |
| 16156 | Aneroid manual sphygmomanometer | A device designed to measure blood pressure consisting of an inflatable cuff that fits around a limb (arm or thigh), an inflation bulb for controlling the air pressure within the cuff, an aneroid manometer, and tubing. The aneroid manometer consists of a metal bellows, which expands as the pressure in the cuff increases, and a mechanical amplifier that transmits this expansion through a lever to an indicator needle, which rotates around a circular, calibrated scale. The manometer may be mounted to a wall, placed on a table, or hand held (portable); blood pressure measurement is taken in conjunction with a stethoscope. | No | Active |
| 38727 | General-purpose surgical scissors, reusable | A hand-held manual surgical instrument designed to cut/dissect a variety of tissues during open surgery and having no dedication to a specific anatomy or clinical use; it might in addition be intended for cutting materials associated with surgery (e.g., sutures). It is comprised of two pivoted shearing blades with handles, whereby the blades cut as the sharpened edges pass one another as they are closed; some types may have blades that cross over to expose a sharp edge for slicing tissue like a scalpel. It is typically made of metal and is available in various designs and sizes, and some types can have carbide inserts along the cutting edges. This is a reusable device. | No | Active |
| 38832 | Hand-held examination/treatment light | A small hand-held battery-powered light intended to beused as a personal light source to provide light for local examination, inspection, and treatment of the patient. It may be torch-like in design and can have a magnifying lens to augment the lighting effect. It will typically be found in an examination room, doctor's office, on a medical trolley, in an emergency kit, or carried in a pocket. This is a reusable device. | No | Active |
| 58128 | Limb tourniquet, manual, single-use | A strap or tubing intended to be wrapped around a patient's limb (arm or leg) and manually tightened to reduce blood circulation to or from the portion of the limb distal to where the device is applied. It is typically used by emergency medical services (EMS) for emergency blood loss prevention or for routine blood sampling. It typically does not include latex and may be available in a variety of designs (e.g., Velcro or a self-locking buckle, synthetic rubber band). This is a single-use device. | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00845821025838 | GS1 |
Customer Contacts
- Phone
- +1(888)822-8293
- [email protected]