FDA UDI
In Commercial Distribution
🇺🇸 United States
OsteoMed
DI: 00845694089777
·
Model: 306-2434-SP
·
OSTEOMED LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- OsteoMed
- Primary DI
- 00845694089777
- Version / Model
- 306-2434-SP
- Catalog Number
- 306-2434-SP
- Company Name
- OSTEOMED LLC
- Labeler DUNS
- 606417780
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-06-09
- Public Version
- 4
- Public Version Date
- 2024-02-19
- Public Version Status
- Update
- Public Device Record Key
- 43e3d742-8852-42ef-942d-5da54b16aa3b
Device Description
2.4 x 34mm Lag Screw, Sterile
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HWC | Screw, fixation, bone | Orthopedic | 888.3040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46649 | Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial | A collection of small sheets of firm material and bone screws intended to be implanted onto fractured bone fragments to bridge and stabilize the fracture gap, and shield the site from stress as the bone heals. The components are made of a material that is not chemically degraded or absorbed by natural body processes (includes implant grade metal such as surgical steel, titanium alloy, or carbon fibre); it does not include an antimicrobial agent(s). Tools for implantation may be included. The device is typically used to treat traumatic or pathological orthopaedic fractures; it may also be used to temporarily augment bone following a lengthening procedure, or for arthrodesis (joint fusion). | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00845694089777 | GS1 |
Customer Contacts
- Phone
- +1(800)456-7779 ext. 1
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 34 | Millimeter |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 59 – 86 Degrees Fahrenheit