FDA UDI
In Commercial Distribution
🇺🇸 United States
Verrata Plus
DI: 00845225002879
·
Model: 10185P
·
Philips Image Guided Therapy Corporation
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Verrata Plus
- Primary DI
- 00845225002879
- Version / Model
- 10185P
- Catalog Number
- 10185P
- Company Name
- Philips Image Guided Therapy Corporation
- Labeler DUNS
- 018860556
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-23
- Public Version
- 8
- Public Version Date
- 2023-07-24
- Public Version Status
- Update
- Public Device Record Key
- cb63eac4-d7a0-4e46-9ab3-c03610f376af
Device Description
Verrata Plus Pressure Guide Wire
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DQX | Wire, Guide, Catheter | Cardiovascular | 870.1330 | 2 |
| DXO | Transducer, Pressure, Catheter Tip | Cardiovascular | 870.2870 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 15071 | Catheter-tip transducer, pressure | A device intended to be incorporated into the distal end of a catheter (not included) to measure pressure. It typically consists of a pressure sensor (e.g., a flexible membrane or diaphragm) and a means to convert the detected pressure into electronic signals or possibly ultrasonic signals which are transmitted via a cable or wireless to an external parent device (e.g., a manometer) that processes the signals and displays the results. It is used for invasive measurement of pressure in places such as the central and/or peripheral vasculature, cranium, uterus (typically during labour), pleura, and also in the urinary bladder/urethra (e.g., during urodynamic tests). This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00845225002879 | GS1 |
Customer Contacts
- Phone
- (800) 228-4728
- [email protected]
Premarket Submissions
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Outer Diameter | 0.014 | Inch | |
| Length | 185 | Centimeter |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions