FDA UDI
In Commercial Distribution
🇺🇸 United States
uSpO2
DI: 00843997008853
·
Model: 3849
·
MASIMO CORPORATION
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- uSpO2
- Primary DI
- 00843997008853
- Version / Model
- 3849
- Catalog Number
- 3849
- Company Name
- MASIMO CORPORATION
- Labeler DUNS
- 780421038
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-09-04
- Public Version
- 4
- Public Version Date
- 2023-11-17
- Public Version Status
- Update
- Public Device Record Key
- 9075b151-819b-473e-952d-40c89eda80d7
Device Description
uSpO2 Masimo SET Oximetry Cable, 5-Pin Medi-Snap Connector, 6', Masimo
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DQA | Oximeter | Cardiovascular | 870.2700 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36654 | Rigid optical ureteroscope | An endoscope with a rigid inserted portion intended for the visual examination and treatment of the ureter, (the upper urinary tract that connects the kidney to the bladder). It is inserted through the external urethral orifice and bladder during ureteroscopy. Anatomical images are transmitted to the user through relayed lens optics or a fibreoptic bundle. This device is typically used for biopsies, endoscopic lithotripsy, treatment of upper urinary tract malignancies, incising strictures, and repairing ureteropelvic junction obstructions. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00843997008853 | GS1 |
Customer Contacts
- Phone
- +1(949)297-7498
- [email protected]
Storage Conditions
- Type
- Handling Environment Humidity
- Temperature Range
- 10 – 95 Percent (%) Relative Humidity
- Type
- Handling Environment Temperature
- Temperature Range
- -40 – 70 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -40 – 70 Degrees Celsius