FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Knee-Lok Positioning Cushion
DI: 00841439103111
·
Model: MTAKS01
·
MEDTEC, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Knee-Lok Positioning Cushion
- Primary DI
- 00841439103111
- Version / Model
- MTAKS01
- Catalog Number
- MTAKS01
- Company Name
- MEDTEC, INC.
- Labeler DUNS
- 103977526
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-08-02
- Public Version
- 5
- Public Version Date
- 2019-03-20
- Public Version Status
- Update
- Public Device Record Key
- 3c333e04-424a-4e92-aba7-9c13a5c82f70
- Distribution End Date
- 2019-03-20
Device Description
Reusable non-sterile (40.6 x 40.6 x 21.4cm) cushion
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| IXQ | Table, radiographic, stationary top | Radiology | 892.1980 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 40900 | Radiological arm/leg positioner | A device designed to ensure adequate positioning and immobilization of the patient's arms and/or legs during diagnostic imaging procedures, image-guided surgical or interventional procedures, and/or radiation therapy procedures. It may include various configurations such as a frame, board, cushion, preformed pad, or shoulder tension rope, strap, or handle grip that may also be used to facilitate reproducible positioning for serial imaging studies or serial radiation therapy treatments. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00841439103111 | GS1 |
Customer Contacts
- Phone
- +1(712)737-8688
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K973842 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Width | 16 | Inch | |
| Length | 16 | Inch |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep away from sunlight