FDA UDI
In Commercial Distribution
🇺🇸 United States
NA
DI: 00841379155102
·
Model: FFBA00L60
·
HYHTE HOLDINGS, INC.
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- NA
- Primary DI
- 00841379155102
- Version / Model
- FFBA00L60
- Catalog Number
- FFBA00L60
- Company Name
- HYHTE HOLDINGS, INC.
- Labeler DUNS
- 073029645
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-07-23
- Public Version
- 1
- Public Version Date
- 2021-08-02
- Public Version Status
- New
- Public Device Record Key
- 7a2b6728-7ffa-4e29-8abd-80a0162dff0d
Device Description
LEFT OFFSET HOOK
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NKG | Posterior Cervical Screw System | Orthopedic | 888.3075 | 2 |
| KWP | Appliance, Fixation, Spinal Interlaminal | Orthopedic | 888.3050 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 65115 | Bone-screw internal spinal fixation system hook | An implantable component of a bone-screw internal spinal fixation system that has a curved (hook-shaped) design intended to provide immobilization and stabilization of spinal segments in the treatment of various spinal instabilities or deformities, and also used as an adjunct to spinal fusion [e.g., for degenerative disc disease (DDD)]. This component is typically made of metal [e.g., titanium (Ti)] and placed/hooked around the lamina or pedicle of a vertebra, without penetration (i.e., not a screw), to provide a stable connection for the system’s rod; the rod is typically stabilized in the U-shaped hook head with a small lid or screw. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00841379155102 | GS1 |
Customer Contacts
- Phone
- 7608148047
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K171250 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Outer Diameter | 6 | Millimeter |