FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Tearaway Introducer Set
DI: 00841268102408
·
Model: INT-107-90
·
GALT MEDICAL CORP.
Product Codes
1
GMDN Terms
1
Identifiers
3
Pkg Device Count
1
Basic Information
- Brand Name
- Tearaway Introducer Set
- Primary DI
- 00841268102408
- Version / Model
- INT-107-90
- Catalog Number
- INT-107-90
- Company Name
- GALT MEDICAL CORP.
- Labeler DUNS
- 943156836
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-08-09
- Public Version
- 4
- Public Version Date
- 2021-03-08
- Public Version Status
- Update
- Public Device Record Key
- e802260f-4103-49c1-afaf-81f2a8c3c908
- Distribution End Date
- 2021-03-05
Device Description
Tearaway Introducer Set
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Ethylene Oxide
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DYB | Introducer, Catheter | Cardiovascular | 870.1340 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 58865 | Vascular catheter introduction set, nonimplantable | A collection of sterile, nonimplantable, invasive devices intended to provide percutaneous vascular access to enable introduction of a catheter (not included) into the vascular system. It includes a non-steerable introducer sheath with an inner obturator/dilator, and typically an additional access device(s) [e.g., guidewire, introducer needle, syringe, additional dilators] which may include a haemostatic valve to control blood loss, usually to enable arterial access. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 20841268102402 | GS1 | Shipper Box | 100 | Not in Commercial Distribution | 2021-03-05 |
| Package | 10841268102405 | GS1 | Shelf Box | 10 | Not in Commercial Distribution | 2021-03-05 |
| Primary | 00841268102408 | GS1 |
Customer Contacts
- Phone
- 800-639-2800
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Catheter Gauge | 9 | French |