FDA UDI
In Commercial Distribution
🇺🇸 United States
PECTUS SYSTEM
DI: 00841036095673
·
Model: 01-3925
·
BIOMET MICROFIXATION, INC
Product Codes
1
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- PECTUS SYSTEM
- Primary DI
- 00841036095673
- Version / Model
- 01-3925
- Catalog Number
- 01-3925
- Company Name
- BIOMET MICROFIXATION, INC
- Labeler DUNS
- 046189866
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-06-15
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- 1c69488a-84b7-45bf-90bd-8db7e0181eda
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HRS | Plate, fixation, bone | Orthopedic | 888.3030 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 42997 | Surgical instrument/implant rack | A device designed as a small case, typically with a hinged lid that can be closed to protect the contents (i.e., surgical instruments and/or implantable devices such as plates or screws), and an integral rest(s) with grooves or notches in the upper edge so that the contents can be securely placed, protected, and organized. The lid or rest may be set at an angle to facilitate instrument/implant access during surgical procedures or sterilization. The device is typically be made of stainless steel or a suitable plastic material so that it can be sterilized. This is a reusable device. | No | Active |
| 61522 | Funnel chest remodelling bar | A non-sterile implantable device intended to be used to reduce the deformity of pectus excavatum (funnel chest) by applying outward force from a position deep to the sternum to reposition the sternum; it is typically used in paediatric patients and surgically removed when remodelling is evident (after 2-3 years). It is a thin curved bar, with or without serrations, made of metal [e.g., stainless steel, titanium (Ti)] that can be anchored with wires or with stabilizer plates laterally on the rib cage. This is a single-patient device intended to be sterilized prior to use. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00841036095673 | GS1 |
Customer Contacts
- Phone
- +1(904)741-4400
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K972420 | 000 |