FDA UDI
In Commercial Distribution
🇺🇸 United States
DISTRACTION SYSTEM
DI: 00841036090975
·
Model: 01-3232
·
BIOMET MICROFIXATION, INC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- DISTRACTION SYSTEM
- Primary DI
- 00841036090975
- Version / Model
- 01-3232
- Catalog Number
- 01-3232
- Company Name
- BIOMET MICROFIXATION, INC
- Labeler DUNS
- 046189866
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-06-15
- Public Version
- 4
- Public Version Date
- 2019-09-23
- Public Version Status
- Update
- Public Device Record Key
- 9bd9eb2b-de33-4846-a3d1-5e5a0d1e4718
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MQN | EXTERNAL MANDIBULAR FIXATOR AND/OR DISTRACTOR | Dental | 872.4760 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47635 | Implantable craniofacial bone distractor | An implantable or partially-implantable device intended to temporarily distract (force apart) the two bone surfaces of the mandible (the lower jawbone) or maxilla (the upper jawbone) during craniomaxillofacial (CMF) distraction. It functions as a single-patient bone lengthening/augmentation device for the correction of congenital deficiencies or post-traumatic defects when gradual bone augmentation is required. It typically consists of a metal tube in which a right- and left-hand threaded rod rotates and to which are attached two craniofacial fixation plates that are surgically screwed to either side of the fracture. A small tip guard may be included to protect against inadvertent rotation. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00841036090975 | GS1 |
Customer Contacts
- Phone
- +1(904)741-4400
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K992952 | 000 |