FDA UDI
In Commercial Distribution
🇺🇸 United States
NA
DI: 00840682138284
·
Model: LATERAL LARGE GRID BREAST BIOPSY PLATE
·
USA INSTRUMENTS, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- NA
- Primary DI
- 00840682138284
- Version / Model
- LATERAL LARGE GRID BREAST BIOPSY PLATE
- Company Name
- USA INSTRUMENTS, INC.
- Labeler DUNS
- 804517571
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-12-01
- Public Version
- 4
- Public Version Date
- 2019-03-11
- Public Version Status
- Update
- Public Device Record Key
- dab94869-6f80-4ff5-a3b0-e9b6ce412b26
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LNH | System, nuclear magnetic resonance imaging | Radiology | 892.1000 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 40899 | Radiological breast positioner, non-wearable | A device that is specifically designed to ensure adequate positioning and immobilization of the female patient's breast(s) and chest during diagnostic imaging procedures, image-guided surgical or interventional procedures, and/or radiation therapy procedures. The device is in the form of a frame, board, cushion, or preformed pad (non-wearable device) and may also be used to facilitate reproducible positioning for serial imaging studies or serial radiation therapy treatments. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00840682138284 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K041695 | 000 |