FDA UDI
In Commercial Distribution
🇺🇸 United States
Black & Black Surgical
DI: 00840329832803
·
Model: B65227X
·
BLACK & BLACK SURGICAL, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Black & Black Surgical
- Primary DI
- 00840329832803
- Version / Model
- B65227X
- Catalog Number
- B65227X
- Company Name
- BLACK & BLACK SURGICAL, INC.
- Labeler DUNS
- 004382282
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-06-02
- Public Version
- 1
- Public Version Date
- 2023-06-12
- Public Version Status
- New
- Public Device Record Key
- 0bbebb09-aa31-4f92-af13-b5fdc0cfc9da
Device Description
B&B E-P ELECTROSURGICAL DISSECTOR; 14.5''(36.5CM), SPECIAL "C" CURVE
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GEI | Electrosurgical, Cutting & Coagulation & Accessories | General, Plastic Surgery | 878.4400 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62061 | Endoscopic electrosurgical electrode, monopolar, reusable | An invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic, arthroscopic) surgery. It available in a variety of forms (e.g., exchangeable electrode for electrosurgical forceps, rigid electrode, flexible endoscopic probe) which may include a lumen for suction/irrigation. It does not include a handpiece/housing and has no electrical or mechanical controls (e.g., does not include controlling ring-handles); it is not intended for gas-enhanced electrosurgery. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00840329832803 | GS1 |
Customer Contacts
- Phone
- +1 (770)414-4880
- [email protected]