FDA UDI
In Commercial Distribution
🇺🇸 United States
Hayden Medical
DI: 00840319747483
·
Model: 280-104
·
Hayden Medical, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Hayden Medical
- Primary DI
- 00840319747483
- Version / Model
- 280-104
- Catalog Number
- 280-104
- Company Name
- Hayden Medical, Inc.
- Labeler DUNS
- 618214410
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-03-22
- Public Version
- 1
- Public Version Date
- 2023-03-30
- Public Version Status
- New
- Public Device Record Key
- b34e8c70-7cd3-465f-b7c6-35687dba4cc3
Device Description
Barr Fistula Probe, with 8" (20cm) sterling shaft, eye at tip, 11-1/2" (28.8cm) overall
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FZX | Guide, surgical, instrument | General, Plastic Surgery | 878.4800 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62126 | Tracheoesophageal fistula gauge | A non-sterile, hand-held, manual non-surgical instrument intended to be transiently inserted into a tracheoesophageal fistula (puncture) for measuring its length to determine appropriate tracheoesophageal speech valve size prior to placement; it may also be intended to temporarily dilate the fistula to facilitate insertion of the speech valve. It a synthetic polymer cylindrical shaft with graduated markings, attached to a handle, designed to be manually inserted via the tracheostoma by a clinician; devices intended to assist insertion may be included. This is a reusable device intended to be sterilized prior to use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00840319747483 | GS1 |
Customer Contacts
- Phone
- +1(661)296-7200
- [email protected]