FDA UDI
In Commercial Distribution
🇺🇸 United States
Ace Medical
DI: 00840217906210
·
Model: AA0032005
·
Ebner Medical, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Ace Medical
- Primary DI
- 00840217906210
- Version / Model
- AA0032005
- Company Name
- Ebner Medical, LLC
- Labeler DUNS
- 106135367
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-02-17
- Public Version
- 3
- Public Version Date
- 2024-01-29
- Public Version Status
- Update
- Public Device Record Key
- c913ae25-6060-4805-bc22-a520f0f1b67d
Device Description
Basket Liposuction Cannulas 2mm x 5cm Luer Lock
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GEA | Cannula, Surgical, General & Plastic Surgery | General, Plastic Surgery | 878.4800 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 38749 | Surgical/emergency suction cannula, non-illuminating, reusable | An atraumatic, invasive, hand-operated, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intrauterine, or liposuction procedures, and is neither an ophthalmic nor an intravascular device; it is not designed for surgical irrigation. Sometimes referred to as a suction tube or tip, it may incorporate a handle with side valve(s)/hole(s), and may be provided with a stylet, sheath, and/or connection tubing; it does not include a light source or fibreoptic bundle. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00840217906210 | GS1 |
Customer Contacts
- Phone
- 8008220314
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 5 | Centimeter | |
| Outer Diameter | 2 | Millimeter |