FDA UDI
In Commercial Distribution
🇺🇸 United States
BR Surgical, LLC
DI: 00840183521189
·
Model: BR11-30820
·
BR Surgical, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- BR Surgical, LLC
- Primary DI
- 00840183521189
- Version / Model
- BR11-30820
- Catalog Number
- BR11-30820
- Company Name
- BR Surgical, LLC
- Labeler DUNS
- 134781207
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-05-02
- Public Version
- 1
- Public Version Date
- 2023-05-10
- Public Version Status
- New
- Public Device Record Key
- c9d2546d-1e84-4772-bdae-5d29d06a0099
Device Description
DEBAKEY Atraumatic Tissue Forceps, 2.0x2.5mm tip, 8"
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Ethylene Oxide", "Moist Heat or Steam Sterilization"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GEN | Forceps, General & Plastic Surgery | General, Plastic Surgery | 878.4800 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62466 | Surgical soft-tissue manipulation forceps, tweezers-like, reusable | A hand-held, manual, open-surgery instrument designed to facilitate grasping and manipulation of soft-tissues. It has a tweezers-like design (may be a micro/fine instrument) with variously designed tips at the working end, whereby the blades are designed to be opened/closed by squeezing between the fingers (i.e., without ring handles). It is made of high-grade stainless steel, available in various sizes, and may have carbide inserts at the working end. It is not an electrosurgical device and not dedicated to ophthalmic surgery. This is a reusable device intended to be sterilized prior to use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00840183521189 | GS1 |
Customer Contacts
- Phone
- 1-904-642-1366
- [email protected]