FDA UDI
In Commercial Distribution
🇺🇸 United States
FibFix
DI: 00840124517684
·
Model: TN-FN-8537-S
·
FUSION ORTHOPEDICS, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- FibFix
- Primary DI
- 00840124517684
- Version / Model
- TN-FN-8537-S
- Catalog Number
- TN-FN-8537-S
- Company Name
- FUSION ORTHOPEDICS, LLC
- Labeler DUNS
- 080307067
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2026-04-09
- Public Version
- 1
- Public Version Date
- 2026-04-17
- Public Version Status
- New
- Public Device Record Key
- 09ff828b-e556-44d7-8c7a-96aba2669dce
Device Description
Drill Sleeve Cannulated 3.7mm (Sterile)
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- Yes
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Radiation Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LXH | Orthopedic Manual Surgical Instrument | Orthopedic | 888.4540 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47831 | Orthopaedic implantation sleeve, reusable | A hand-held tubular surgical device designed to be used during an orthopaedic implantation procedure to hold/grip an implant (e.g., an orthopaedic bone screw), facilitate the acceptance of an orthopaedic instrument (e.g., a screwdriver or a smaller diameter sleeve) through it, stabilize an instrument/implant coupling, and/or protect the surgeon's gloved hand or patient tissue. It is not primarily intended to place, angle, and guide a rotating surgical drill. It is typically made of high-grade stainless steel and/or synthetic materials and is available in various sizes and lengths. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00840124517684 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K252961 | 000 |