FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Z-Stent
DI: 00827002248694
·
Model: G24869
·
COOK INCORPORATED
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Z-Stent
- Primary DI
- 00827002248694
- Version / Model
- G24869
- Catalog Number
- EZS-25-8-70-AR
- Company Name
- COOK INCORPORATED
- Labeler DUNS
- 079720472
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-11-03
- Public Version
- 3
- Public Version Date
- 2023-07-14
- Public Version Status
- Update
- Public Device Record Key
- 42b79071-4f51-4daa-8bea-400e55d3f4f8
- Distribution End Date
- 2016-12-05
Device Description
Z-Stent Esophageal with Dua Anti-Reflux Valve
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| ESW | PROSTHESIS, ESOPHAGEAL | General, Plastic Surgery | 878.3610 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61751 | Polymer-metal oesophageal stent | A non-bioabsorbable, expandable, tubular device intended to be implanted into the oesophagus to maintain luminal patency in strictures, prevent tumour in-growth, seal oesophageal fistulas, reduce acute bleeding from oesophageal varices, and/or to treat other lesions causing oesophageal leakage (e.g., anastomotic). It consists of a mesh structure made of metal which is covered/lined with a synthetic polymer material (e.g., silicone) that prevents lateral flow and tissue ingrowth and facilitates removability. It is typically expanded in situ (e.g., self-expands) and disposable devices intended to assist implantation may be included. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00827002248694 | GS1 |
Customer Contacts
- Phone
- +1(812)330-5494
- [email protected]
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Store in dark, dry, cool place