FDA UDI
In Commercial Distribution
🇺🇸 United States
Bosma Enterprises
DI: 00818634020352
·
Model: 10-8020BIO
·
Bosma Enterprises
Product Codes
1
GMDN Terms
5
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Bosma Enterprises
- Primary DI
- 00818634020352
- Version / Model
- 10-8020BIO
- Catalog Number
- 10-8020BIO
- Company Name
- Bosma Enterprises
- Labeler DUNS
- 878070325
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-07-02
- Public Version
- 2
- Public Version Date
- 2023-11-03
- Public Version Status
- Update
- Public Device Record Key
- aa508ffc-a948-45b9-9526-8032cad12906
Device Description
Accelerate-OR BIO Kit; Each Kit Includes Sahara OR Table and Draw/Lift Sheet, Patient Strap, STAT-BLOC Disposable Antimicrobial Impervious Armboard Cover with Straps (2), 40x40 Clear 2 mil Draw Tape Bag, 40x40 Blue 2 mil Draw Tape Bag, 24x32 Clear Liner 1.0 mil 15 gal Bag (4), 38x47 Buff Color 1.8 mil Waste Bag (3), 18x24 Clear 2 mil 100% Cotton Double Drawstring Bag, Suction Tubing (2), Suction Liner 3000cc (2) and 16 oz Banded Disposable Rayon Mop Head.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| PWU | Clean-Up Kit | General Hospital | 880.6890 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 65175 | Operating room turnover kit | A collection of devices intended to be used to efficiently clean and prepare an operating room (OR) for a subsequent surgical procedure. It typically includes patient oriented items such as absorbent covers/drapes for the operating table and patient positioners (e.g., headrest), operating room cleaning items such as cleaning mop heads and pads, and refuse containment items such as surgical waste and biohazard bags/buckets. This is a single-use device. | No | Active |
| 37165 | Patient transfer/turning sheet, single-use | A manual device in the form of a sturdy sheet intended to be used by healthcare professionals to assist in the physical movement and/or transfer of a recumbent patient from one position/location to another. The device may operate using sliding/rolling and/or lifting techniques to move the patient upon it. It is typically made of plastics or textiles and may incorporate handles. This is a single-use device. | No | Active |
| 44851 | Limb/torso/head restraint, single-use | A non-rigid device, typically a strap(s), band(s) or garment-like, intended to be temporarily placed on or around one or more parts of a patient’s body (e.g., torso, limbs, head) to restrict movement, to facilitate patient positioning and stabilization during a medical procedure, and/or to prevent injury/hazards while potentially permitting limited movement. It is made of various materials (e.g., fabric, nylon, leather, or foam) and typically anchored to a fixture or furniture part (e.g., a bedrail, operating table). It is not intended for immobilization of specific joint. This is a single-use device. | No | Active |
| 16779 | Suction/irrigation tubing, single-use | A length of flexible noninvasive tube, typically made of synthetic polymer material(s), intended to interface between suction and/or irrigation devices (e.g., catheters, pumps, collection bottles) during a medical/surgical procedure (not dedicated to ophthalmic use); it might additionally be intended for use during reusable device reprocessing. The tubing may be provided in rolls from which required lengths are cut, or may be provided in predetermined lengths with connectors; it does not include additional associated items such as a clamp, spike, or bag (i.e., not a tubing set). This is a single-use device. | No | Active |
| 44942 | Suction system canister liner | A device made of disposable materials used to cover the inner surface of a suction system reusable canister, for the collection of substances such as blood, bodily fluids, rinsing fluids, body tissue, or gas (e.g., laser plume evacuation) from a site of operation. The device may be soft-walled, or it may have walls of semi-rigid plastic with a dedicated lid. Together with the canister, it can be used singularly, or in a connected series to provide greater capacity. This device should be discarded, including its contaminated waste content, according to the environmental legislation by which the user is bound (e.g., incineration, recycling, landfill). This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00818634020352 | GS1 | ||||
| Package | 10818634020359 | GS1 | Case | 8 | In Commercial Distribution |
Customer Contacts
- Phone
- 800-362-5463
- [email protected]
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Avoid excessive heat. Keep dry.