FDA UDI
In Commercial Distribution
🇺🇸 United States
Alere iCup Dx 14
DI: 00817405020010
·
Model: I-DX-1147-022
·
Instant Technologies, Inc.
Product Codes
12
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Alere iCup Dx 14
- Primary DI
- 00817405020010
- Version / Model
- I-DX-1147-022
- Catalog Number
- I-DX-1147-022
- Company Name
- Instant Technologies, Inc.
- Labeler DUNS
- 019410187
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-19
- Public Version
- 8
- Public Version Date
- 2022-06-10
- Public Version Status
- Update
- Public Device Record Key
- 26f79adf-a895-4fd9-a923-af888146d53d
Device Description
Urine Drug Screen Cup for detection of 14 drugs, Amphetamine, Barbiturate, Benzodiazepine, Buprenorphine, Cocaine, Ecstasy, Marijuana, Methamphetamine, Methadone, Morphine, Oxycodone, Phencyclidine, Propoxyphene and Tricyclic Antidepressants, CLIA Waived
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JXN | Enzyme Immunoassay, Propoxyphene | Clinical Toxicology | 862.3700 | 2 |
| LAF | Gas Chromatography, Methamphetamine | Clinical Toxicology | 862.3610 | 2 |
| DJR | Enzyme Immunoassay, Methadone | Clinical Toxicology | 862.3620 | 2 |
| JXM | Enzyme Immunoassay, Benzodiazepine | Clinical Toxicology | 862.3170 | 2 |
| DIS | Enzyme Immunoassay, Barbiturate | Clinical Toxicology | 862.3150 | 2 |
| DKZ | Enzyme Immunoassay, Amphetamine | Clinical Toxicology | 862.3100 | 2 |
| DIO | Enzyme Immunoassay, Cocaine And Cocaine Metabolites | Clinical Toxicology | 862.3250 | 2 |
| LDJ | Enzyme Immunoassay, Cannabinoids | Clinical Toxicology | 862.3870 | 2 |
| DJC | Thin Layer Chromatography, Methamphetamine | Clinical Toxicology | 862.3610 | 2 |
| DJG | Enzyme Immunoassay, Opiates | Clinical Toxicology | 862.3650 | 2 |
| LCM | Enzyme Immunoassay, Phencyclidine | Unknown | U | |
| LFH | U.V. Spectrometry, Tricyclic Antidepressant Drugs | Clinical Toxicology | 862.3910 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46994 | Multiple drugs of abuse IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of multiple drugs of abuse in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00817405020010 | GS1 |
Customer Contacts
- Phone
- 1-800-340-4029
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K122633 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 59 – 86 Degrees Fahrenheit