FDA UDI
In Commercial Distribution
🇺🇸 United States
Surge Cardiovascular
DI: 00817278010545
·
Model: TOU-7904S
·
Med Michigan Holdings, LLC
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Surge Cardiovascular
- Primary DI
- 00817278010545
- Version / Model
- TOU-7904S
- Catalog Number
- TOU-7904S
- Company Name
- Med Michigan Holdings, LLC
- Labeler DUNS
- 097462979
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-23
- Public Version
- 3
- Public Version Date
- 2022-09-21
- Public Version Status
- Update
- Public Device Record Key
- 9d923a31-f0e2-4978-b8e6-dfbb46ae31a9
Device Description
Adult Tourniquet Kit with Snare, 1 red, 1 blue, 7" length
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Ethylene Oxide
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GDJ | Clamp, Surgical, General & Plastic Surgery | General, Plastic Surgery | 878.4800 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 58830 | Cardiopulmonary bypass cannula holder set | A collection of sterile devices intended to help secure a cardiopulmonary bypass cannula to the underlying tissue in the operative field to minimize displacement of the cannula during cardiopulmonary bypass surgery. Popularly known as a `snugger?, it typically consists of a number of colour-coded plastic tubes which can be cut to length, and a metal wire snare. The snare is intended to grasp a purse-string suture and to pull it taut through the tube; a holding suture is tied around the tube and the cannula to keep the cannula in place. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 10817278010542 | GS1 | Case | 40 | In Commercial Distribution | |
| Primary | 00817278010545 | GS1 |