FDA UDI
In Commercial Distribution
🇺🇸 United States
NOVEOS Substrate Mix Container Pack
DI: 00816879023091
·
Model: 118877-001
·
HYCOR BIOMEDICAL LLC
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- NOVEOS Substrate Mix Container Pack
- Primary DI
- 00816879023091
- Version / Model
- 118877-001
- Company Name
- HYCOR BIOMEDICAL LLC
- Labeler DUNS
- 010558476
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-01-11
- Public Version
- 2
- Public Version Date
- 2023-11-03
- Public Version Status
- Update
- Public Device Record Key
- b4b94db6-ef4a-4e0a-80c6-4049dabdaefb
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DHB | System, Test, Radioallergosorbent (Rast) Immunological | Immunology | 866.5750 | 2 |
| JJE | Analyzer, Chemistry (Photometric, Discrete), For Clinical Use | Clinical Chemistry | 862.2160 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35413 | General laboratory container, reusable | A container (e.g., test tube, bottle, cup, assay tray with large wells) intended to be used as a non-dedicated receptacle to hold consumable laboratory substances (e.g., reagents, buffers), biological specimens, and other materials associated with in the laboratory; it is not intended for in vitro diagnostic procedures. It is designed to withstand an extremely high-temperature environment (e.g., autoclaving) to enable repeated sterilization. It is typically made of high-temperature-resistant plastic or glass and may be used on the benchtop for manual procedures, or on-board automated liquid handling instruments or analysers (e.g., tissue culture). This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00816879023091 | GS1 |
Customer Contacts
- Phone
- 800-382-2527
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K182479 | 000 |