FDA UDI
In Commercial Distribution
🇺🇸 United States
Spacer 5cm Synthetic 5 piece
DI: 00815165020271
·
Model: Spacer 5cm Synthetic 5 piece
·
Eckert & Ziegler Bebig, Inc.
Product Codes
1
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Spacer 5cm Synthetic 5 piece
- Primary DI
- 00815165020271
- Version / Model
- Spacer 5cm Synthetic 5 piece
- Catalog Number
- SS9X5CMS
- Company Name
- Eckert & Ziegler Bebig, Inc.
- Labeler DUNS
- 021125001
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-27
- Public Version
- 3
- Public Version Date
- 2019-08-15
- Public Version Status
- Update
- Public Device Record Key
- d3825484-3a6a-4191-80b8-66ded749e6f0
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- Yes
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KXK | Source, Brachytherapy, Radionuclide | Radiology | 892.5730 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 38299 | Manual brachytherapy system | An assembly of therapeutic, independent devices, manually brought together and intended to deliver a palliative or therapeutic radiation dose to an anatomical region from radionuclide sources. Medical personnel manually place multiple radioactive sources in appliances and applicators for either permanent or temporary delivery at the topical, interstitial, intraluminal, or intracavitary brachytherapy treatment site. The radioactive source(s) assemblies contain naturally occurring, reactor produced, or accelerator produced radionuclides that are in the form of, e.g., encapsulated, embedded, sealed, wire, plated or foil sources, contained radioactive liquids, gels or gas. | No | Active |
| 46844 | Brachytherapy source spacer | A sterile, bioabsorbable device designed to separate radioactive sources of the seed type that are permanently implanted in close proximity to a selected localized tumour, to increase the distribution of radioactivity to the tumour. It typically has a cylindrical form (of around 0.5 cm in length and less than 1 mm in diameter) and is made of bioabsorbable polymer materials. It may be used for the primary treatment of tumours (e.g., prostate cancer), or to treat unresectable tumours, recurring tumours, or residual disease. It is typically placed in the body by means of a remote-afterloading applicator using ultrasonic or fluoroscopic guidance. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00815165020271 | GS1 |
Customer Contacts
- Phone
- 203-262-0571
- [email protected]