FDA UDI
In Commercial Distribution
🇺🇸 United States
InHealth Technologies; Blom-Singer; Classic
DI: 00813307014522
·
Model: IN 1606-IR
·
Freudenberg Medical, LLC
Product Codes
2
GMDN Terms
5
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- InHealth Technologies; Blom-Singer; Classic
- Primary DI
- 00813307014522
- Version / Model
- IN 1606-IR
- Company Name
- Freudenberg Medical, LLC
- Labeler DUNS
- 120981337
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-01-01
- Public Version
- 3
- Public Version Date
- 2020-06-19
- Public Version Status
- Update
- Public Device Record Key
- 0be122f2-8820-4102-a3d1-8e5ec50f30d3
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| EPE | Brush, Cleaning, Tracheal Tube | Anesthesiology | 868.5795 | 1 |
| EWL | Prosthesis, Laryngeal (Taub) | Ear, Nose, Throat | 874.3730 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62127 | Tracheoesophageal device introducer | A hand-held manual instrument designed to assist in the non-surgical placement of a tracheoesophageal device (e.g., speech valve, speech valve occluder, fistula gauge/dilator). It is a synthetic polymer holder onto which the tracheoesophageal device is distally mounted and directed to the target site through the tracheostoma. It is intended to be used by the patient at home (for non-indwelling devices) and clinician in the healthcare facility (for indwelling devices). This is a single-use device. | No | Active |
| 62134 | Tracheoesophageal device insertion capsule | A non-sterile, smooth, capsule-like device intended to house/cover a tracheoesophageal device (e.g., speech valve, fistula gauge) at the distal end of the introduction assembly, to enable atraumatic insertion of the device into the tracheoesophageal fistula (puncture). It is a synthetic polymer gelatinous casing intended to dissolve in situ for subsequent digestion; disposable devices intended to assist mounting may be included. It is intended to be used in the home and healthcare facility, and may be used in conjunction with a lubricant. This is a single-use device. | No | Active |
| 62096 | Tracheoesophageal speech valve irrigation device | A non-sterile hand-held device intended to be used for the in situ washing of an indwelling tracheoesophageal speech valve by water irrigation to remove organic matter (e.g., phlegm). It is in the form of a water-fillable squeeze bulb with a distal nozzle that is inserted through the tracheostoma into the central lumen of the valve; it is intended to be used routinely by a patient in the home. This is a reusable device. | No | Active |
| 62094 | Tracheoesophageal speech valve, indwelling, non-sterile | A non-sterile device designed to be inserted into a surgically-created tracheoesophageal fistula after total laryngectomy to provide the patient with voice restoration. It is inserted and replaced as needed by a medical professional. It has a double flange (one on the outside of the throat and one on the inside) to hold it in place and includes a one-way valve that protects the airway during swallowing and opens under positive pressure so that air crosses into the oesophagus to produce voice (speech rehabilitation). It is routinely cleaned by the user in situ and assistive cleaning devices (e.g., brush) may be included. This is a single-use device. | No | Obsolete |
| 62095 | Airway device cleaning utensil, invasive | A non-sterile hand-held device intended to be used to clean an in situ airway device (e.g., indwelling tracheoesophageal speech valve, laryngeal airway). It is inserted into the central lumen of the device and typically rotated multiple times to remove organic matter (e.g., phlegm); it may also be used to clean an airway device ex situ (i.e., once it has been removed from the patient). It is in the form of a flexible or rigid handle with distal soft or stiff bristles, fibres or spines, or a swab; it may be used in the home or healthcare facility. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00813307014522 | GS1 |
Customer Contacts
- Phone
- 800-477-5969
- [email protected]