FDA UDI
In Commercial Distribution
🇺🇸 United States
Multi-Analyte Lipid Control Set
DI: 00812137012197
·
Model: L1 x 3mL, L2 x 3mL, L3 x 3mL
·
CLINICAL DIAGNOSTIC SOLUTIONS, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
3
Basic Information
- Brand Name
- Multi-Analyte Lipid Control Set
- Primary DI
- 00812137012197
- Version / Model
- L1 x 3mL, L2 x 3mL, L3 x 3mL
- Catalog Number
- 502-160
- Company Name
- CLINICAL DIAGNOSTIC SOLUTIONS, INC.
- Labeler DUNS
- 048144997
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 3
- Record Status
- Published
- Publish Date
- 2016-10-12
- Public Version
- 3
- Public Version Date
- 2022-03-08
- Public Version Status
- Update
- Public Device Record Key
- d14530a9-ca5f-4851-931c-ef53c4160255
Device Description
This product is intended for in-vitro use in the quality control of HDL, LDL, Apolipoprotein A-1, Apolipoprotein B, and Lipopro-tein (a) methods on clinical chemistry systems. The Multi-Analyte Lipid Control Set is a set of three serum levels. These three levels are to be used exclusively with the CDS HDL Cholesterol Reagent, CDS LDL Cholesterol Reagent, (CDS 501-419 and CDS 501-420) which are assays for the quan-tification of various lipids and lipoproteins in human serum.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- Yes
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JJY | Multi-Analyte Controls, All Kinds (Assayed) | Clinical Chemistry | 862.1660 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44695 | High density lipoprotein (HDL) cholesterol IVD, control | A material which is used to verify the performance of an assay intended to be used for the quantitative measurement of high density lipoprotein (HDL) cholesterol lipid in a clinical specimen. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00812137012197 | GS1 | ||||
| Unit of Use | 00812137012418 | GS1 |
Customer Contacts
- Phone
- 8004533328
- [email protected]
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 2 – 8 Degrees Celsius