Basic Information
- Brand Name
- Pointe Scientific, Inc. ISE Internal Reference
- Primary DI
- 00811727014757
- Version / Model
- HI790-REF
- Catalog Number
- HI790-REF
- Company Name
- HORIBA INSTRUMENTS INCORPORATED
- Labeler DUNS
- 052845583
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-31
- Public Version
- 4
- Public Version Date
- 2025-10-02
- Public Version Status
- Update
- Public Device Record Key
- d54716d3-06ce-440c-87fb-2d91e38df3de
Device Description
For the quantitative determination of sodium, potassium, and chloride in serum. Sodium measurements are used in the diagnosis and treatment of aldosteronism (excessive secretion of the hormone aldosterone), diabetes insipidus (chronic excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison’s disease (caused by destruction of the adrenal glands), dehydration, inappropriate antidiuretic hormone secretion, or other diseases involving electrolyte imbalance. Potassium measurements are used to monitor electrolyte balance in the diagnosis and treatment of disease conditions characterized by low or high blood potassium levels. Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis. 6 x 2L
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JGS | Electrode, Ion Specific, Sodium | Clinical Chemistry | 862.1665 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 59238 | Ion selective electrode (ISE) reference solution IVD, reagent | A substance or reactant intended to be used together with a reference electrode to perform a specific function in an assay that is used for the quantitative measurement of one or multiple electrolytes in a clinical specimen. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00811727014757 | GS1 |
Customer Contacts
- Phone
- 800-445-9853
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K051646 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 15 – 30 Degrees Celsius