FDA UDI
In Commercial Distribution
🇺🇸 United States
CSR Shoulder System
DI: 00811596030353
·
Model: 1226-5036
·
CATALYST ORTHOSCIENCE INC.
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- CSR Shoulder System
- Primary DI
- 00811596030353
- Version / Model
- 1226-5036
- Company Name
- CATALYST ORTHOSCIENCE INC.
- Labeler DUNS
- 079702565
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-01-15
- Public Version
- 2
- Public Version Date
- 2020-09-22
- Public Version Status
- Update
- Public Device Record Key
- 43b6d349-bd5a-4129-8953-49cb988683c5
Device Description
XS Humeral Modular Cut Guide 1
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HSD | Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented | Orthopedic | 888.3690 | 2 |
| KWT | Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented | Orthopedic | 888.3650 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61917 | Osteotomy guide, reusable | A surgical instrument intended to be attached to a bone (e.g., pelvis, femur, tibia, ulna) during an osteotomy procedure (including during joint arthroplasty) to outline/define the desired cut-line and mechanically support/guide the cutting device (e.g., oscillating cutting saw). This is a reusable device intended to be sterilized prior to use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00811596030353 | GS1 |
Customer Contacts
- Phone
- 800-587-5137
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K152825 | 000 |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Sterile instruments should be stored in a limited access area that is well ventilated and provides protection from dust, moisture, insects and extremes in temperature and humidity.