FDA UDI
In Commercial Distribution
🇺🇸 United States
Lantern
DI: 00810832031994
·
Model: 502000-01
·
Orthalign, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Lantern
- Primary DI
- 00810832031994
- Version / Model
- 502000-01
- Catalog Number
- 502000-01
- Company Name
- Orthalign, Inc.
- Labeler DUNS
- 023266163
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-09-12
- Public Version
- 2
- Public Version Date
- 2025-12-08
- Public Version Status
- Update
- Public Device Record Key
- 432e38c5-7f3c-4b9d-9c71-86eba3c12735
Device Description
Lantern Hip, Navigation Unit, Supine ONLY
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| ONN | Intraoperative Orthopedic Joint Assessment Aid | Neurology | 882.4560 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 45200 | Orthopaedic stereotactic surgery system | An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during orthopaedic surgery. The system may include computerized functions to store diagnostic images used for image-guided surgery. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00810832031994 | GS1 |
Customer Contacts
- Phone
- 866-582-0879
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K242616 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- -22 – 140 Degrees Fahrenheit
- Type
- Handling Environment Temperature
- Temperature Range
- -22 – 140 Degrees Fahrenheit