FDA UDI
In Commercial Distribution
🇺🇸 United States
Tenzor Radiolucent Carbon Fiber Spine Positioning Frame
DI: 00810105030297
·
Model: 4-0009-001
·
COMPOSITE MANUFACTURING, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Tenzor Radiolucent Carbon Fiber Spine Positioning Frame
- Primary DI
- 00810105030297
- Version / Model
- 4-0009-001
- Company Name
- COMPOSITE MANUFACTURING, INC.
- Labeler DUNS
- 947090650
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-02-14
- Public Version
- 1
- Public Version Date
- 2020-02-24
- Public Version Status
- New
- Public Device Record Key
- bd6c9ad7-3c3e-4fb5-8a2e-1878919db0f6
Device Description
Radiolucent Spine positioning traction frame. Arcing flexures are used to arc the patients spine while in the prone position to expose the spine for surgical procedures.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| BWN | Table And Attachments, Operating-Room | General, Plastic Surgery | 878.4950 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46762 | Traction table, manual | A mobile, manually-operated, table designed to support a patient and to provide traction for the back muscles and spine (e.g., lumbar, cervical) by a mechanical altering of the table surface geometry. The surface typically consists of sections that can be raised and lowered to manipulate the curvature of the patient?s spine whilst he/she lies in a supine position. Interchangeable traction devices such as head halters, pelvic belts, traction boots, and a traction unit may be used with this table. It is typically used in a healthcare facility. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00810105030297 | GS1 |
Customer Contacts
- Phone
- 9493617580
- [email protected]