FDA UDI
In Commercial Distribution
🇺🇸 United States
CoLink® Sfx
DI: 00810021864181
·
Model: K24 SS211
·
In2Bones USA, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- CoLink® Sfx
- Primary DI
- 00810021864181
- Version / Model
- K24 SS211
- Catalog Number
- K24 SS211
- Company Name
- In2Bones USA, LLC
- Labeler DUNS
- 079700711
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-08-13
- Public Version
- 7
- Public Version Date
- 2025-08-04
- Public Version Status
- Update
- Public Device Record Key
- 7a82d2e3-857a-4eb0-b32b-f0c59ef26654
Device Description
CoLink® Sfx K-wire 0.045in (1.1mm) x 6.0in with KLIP, Sterile
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HTY | Pin, Fixation, Smooth | Orthopedic | 888.3040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 32854 | Orthopaedic bone pin, non-bioabsorbable | A thin, implantable rod intended to be used for the stabilization of a bone fracture or bone grafts, or for an osteotomy or arthrodesis (internal and/or external fixation). It is typically drilled into bone and may be smooth or threaded, solid or cannulated, and/or semi-flexible. Also known as a Kirschner-wire (K-wire), it may in addition be intended to assist with the introduction of a surgical instrument and/or implant; it is not intended for implantation into the intramedullary canal (i.e., not a nail). It is made of a non-bioabsorbable material (e.g., stainless steel). Some designs may have a break-off shank and/or be coated to improve long-term fixation. This is a single-use device. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00810021864181 | GS1 |
Customer Contacts
- Phone
- +1(866)426-6633
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K203698 | 000 |