FDA UDI
In Commercial Distribution
🇺🇸 United States
Healix
DI: 00810005666695
·
Model: CSRW-1000T-350
·
NVISION BIOMEDICAL TECHNOLOGIES, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Healix
- Primary DI
- 00810005666695
- Version / Model
- CSRW-1000T-350
- Company Name
- NVISION BIOMEDICAL TECHNOLOGIES, INC.
- Labeler DUNS
- 047486041
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-08-21
- Public Version
- 2
- Public Version Date
- 2024-02-19
- Public Version Status
- Update
- Public Device Record Key
- 64097656-7a2e-43f4-b5da-09887431b1c8
Device Description
Kwire Trocar 6.0mm - 8.5mm. The HEALIX Compression Screw (HCS) System is indicated for Bone Fractures, Osteotomies, Arthrodesis, Osteochondritis, and Tendon Reattachment. It is intended for, but not limited to, Hand Surgery, Orthopedic Surgery, and Podiatric Surgery but is not intended for attachment or fixation to the posterior elements (pedicles) of the spine.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MDM | Instrument, Manual, Surgical, General Use | General, Plastic Surgery | 878.4800 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35685 | Orthopaedic bone wire | A wire intended for the fixation of bone fractures that may be implanted or used short-term (e.g., to hold a plate in the correct position during an intervention). It may be used: 1) as a cerclage wire to aid bone fixation; 2) in a loop or figure-of-eight configuration to reattach, e.g., the tip of the elbow (olecranon), tibial tubercle, or greater trochanter; 3) to augment bone screw/plate fixation; or 4) as a Kirschner wire or K-Wire to stiffen (arthrodese) a toe or finger. It is made of metal [e.g., stainless steel, cobalt-chrome (Co-Cr)], and may be malleable or rigid; some types include a nut designed to be attached to the wire to prevent wire migration. This is a single-use device. | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00810005666695 | GS1 |
Customer Contacts
- Phone
- (210) 545-3713
- [email protected]